Frequency
Response |
:
|
80
Hz – 20 kHz ( ± 3 dB) |
Frequency
Range |
:
|
50
Hz – 20 kHz (-10 dB) |
Coverage
Pattern |
: |
90° x 50°
rotatable waveguide |
| Directivity
Factor (Q) |
: |
10 |
| Directivity
Index (DI) |
: |
10 dB |
Maximum
Peak Output |
:
|
132
dB SPL 1m |
Transducer
Section |
|
|
Low
Frequency Section |
:
|
JBL
2261FF, 254 mm (10 in) dia., 76 mm (3 in) Dual Coil neodymium Differential
Drive®, Direct Cooled |
Bandpass
Nominal Impedance |
:
|
2
x 2 ohms |
High
Frequency |
:
|
JBL2452H-SL,
100 mm (4 in) titanium damped
diaphragm, 1.5 in. exit. |
Bandpass
Nominal Impedance |
:
|
8
ohms |
System
|
|
|
DPC-2
Internal Amplification Output
(at nominal load) |
:
|
1750
Watts Peak,
875 Watts Continuous |
| DPC-2 Output (Continuous IEC shaped
pink noise into rated load impedance) |
:
|
750LF/125HF
Watts |
DPC-2
Output Section |
:
|
LF:
Dual Bridged Technology™, Class D
HF: Bridged Class D |
Audio
Input connector |
:
|
XLR
with loop-through |
User
Controls |
:
|
80
Hz Subwoofer High Pass Filter. Enable/Disable
0-16 dB input Attenuator with 32 precision 0.5 dB steps |
Signal
Processing |
:
|
DSP
Based, resident in Input Module |
System
Management
|
:
|
DSP
based limiters for mechanical
and thermal protection |
AC
Power
Operating Range |
:
|
90-132 VAC/216-264 VAC, 50/60 Hz
|
AC
Line Voltage |
:
|
50/60 Hz; User Selectable; 120V/240V (-15%, +10%) |
AC
Input Connector |
:
|
Neutrik
PowerCon (NAC 3MPA) |
AC
Loop-thru |
:
|
Neutrik
PowerCon (NAC 3MPB) |
AC
Current Requirement |
:
|
6A per system at 120V, 3A per system at 240V |
Enclosure |
|
|
Box
Construction |
:
|
5/8in.
multi-ply exterior grade
Baltic birch. Internally braced.
Black DuraFlex™ finish.
|
Suspension
System |
:
|
10
M10 Fittings
|
Grille |
:
|
14
Gauge Black powder-coated
perforated steel with foam backing
|
Dimensions
(H x W x D) |
:
|
521
x 293 x 303 mm
20.5 x 11.5 x 11.9 in |
Net
Weight: |
:
|
18.4
kg (40.5 lbs) |